Description
PelPro Low Limit Heat Sensor, KS-5100-1321-AMP
Replacement F110-20F Low Limit Snap Switch Thermodisc for PelPro pellet stoves that feature the DHC board. This limit switch is mounted on the exhaust blower housing and has 2 main functions:
-
Should the fire happen to go out, for any reason, this limit switch will shut the stove off when the exhaust temperature drops below 120°F.
- Upon starting the appliance, the control board has a 15 minute “Lighting Mode”, if the stove exhaust does not reach 120°F in that 15 minutes the stove will shut off.